The HI9814 is a slim, lightweight, and waterproof portable meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature with a single amplified probe. The meter operation is simplified with two buttons. Advanced features including an selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).
The HI9814 is a slim, lightweight, and waterproof portable meter that measures pH, conductivity (EC), total dissolved solids (TDS) and temperature with a single amplified probe. The meter operation is simplified with two buttons. Advanced features including an selectable EC to TDS conversion factor (0.5 - 500 ppm and 0.7 - 700 ppm).
Details:
The HI9814 portable meter features a large multi level LCD which displays both pH, EC or TDS and temperature readings simultaneously. The pH readings are displayed with a 0.01 resolution and an accuracy of +/-0.05 pH while the EC and TDS readings are displayed with a 0.01 mS/cm and 10 ppm (mg/L) resolution and 2% full scale accuracy. The EC range of the HI9814 is from 0.01 to 6.00 mS/cm and TDS is from 0 to 3000 ppm using the 0.5 conversion factor. The EC to TDS conversion factor is selectable 0.5 (500) and 0.7 (700 ppm). A built in temperature sensor allows for automatic temperature compensated measurements of EC and TDS. The HI9814 has many advanced features that are found in more expensive portable instrumentation including automatic calibration, buffer/standard recognition and temperature compensation. The LCD screen has indicators for calibration status and stability, as well as on-screen tutorial messages. The battery percent level is displayed at start up alerting the user to the remaining battery power that is available. The supplied HI1285-7 is a polypropylene body, amplified pH electrode with a built-in EC/TDS and temperature sensors. The amplifier for the pH electrode prevents interference from humidity and sources of electrical noise include circulating pumps, motors and ballasts for grow lights. The HI9814 is a versatile meter designed for hydroponics, greenhouse and agriculture applications.
Simplified one button calibration:
One or two point pH calibration is automatic to a pre-programmed buffer set (4.01, 7.01 and 10.01) or single point pH and EC calibration with the Hanna Quick Cal calibration solution To perform a quick cal calibration simply press and hold the left power/mode button while in measurement mode for three seconds and let go once QUICK CAL is displayed. Once both pH and EC are calibrated CAL OK is displayed and the meter exits to measurement mode.
HI1285-7 polypropylene body amplified pH electrode with built in EC/TDS and temperature sensors:
The HI9814 is supplied with an amplified polypropylene body pH/EC/TDS/temperature probe. The built in amplifier will reduce the effects of electrical noise on the high impedance pH measurement. Examples of sources of electrical noise include circulating pumps, motors and ballasts for grow lights.
3 sensors in a single probe
-pH electrode - Preamplified for resistance to electrical noise including that generated by pumps and ballast
-EC/TDS sensor - amperometric two pole design
-Temperature - NTC sensor for accurate temperature measurement and compensation
Waterproof
-Designed to withstand the humidity of a growing environment
Wide pH Range
-pH range is from 0.00 to 14.00 pH
Selectable EC to TDS conversion factor
-Choice of either a 0.5 or 0.7 conversion factor
-0.5 (500 CF) conversion factor is for an EC reading of 1000 μS/cm = 500 ppm
-0.7 (700 CF) conversion factor is for an EC reading of 1000 μS/cm = 700 ppm
Stability indicator
-Meter displays a clock tag that will disappear when the reading has achieved stability
HOLD button
-Freezes reading on the display to allow recording of measurement
BEPS (Battery Error Prevention System
-Meter will automatically shut off if there is not enough power to get an accurate measurement
pH Range | 0.00 to 14.00 pH |
---|---|
pH Resolution | 0.01 pH |
pH Accuracy | ±0.01 pH |
pH Calibration | automatic, at one or two points using standard buffers (pH 4.01, 7.01,10.01); one point calibration using quick calibration solution |
Conductivity Range | 0.00 to 6.00 mS/cm |
Conductivity Resolution | 0.01 mS/cm |
Conductivity Accuracy | ±2% F.S. |
TDS Range | 0 to 3000 ppm (500 CF); 0 to 3999 ppm (700 CF) |
TDS Resolution | 10 ppm (mg/L) |
TDS Accuracy | ±2% F.S. |
Temperature Range | 0.0 to 60.0°C / 32.0 to 140.0°F |
Temperature Resolution | 0.1°C / 0.1°F |
Temperature Accuracy | ±0.5°C /±1°F |
Temperature Compensation | pH: automatic; EC/TDS: automatic with β set at 1.9%/°C |
EC/TDS Calibration | automatic, one-point at 1.41 mS/cm or 5.00 mS/cm; one point calibration using quick calibration solution |
TDS Conversion Factor | 0.5 (500 ppm) or 0.7 (700 ppm) |
Electrode/Probe | HI1285-7 polypropylene body, pre-amplified multiparameter probe with internal temperature sensor, DIN connector and 1m cable |
Battery Type/Life | 1.5V (3) AAA / approximately 500 hours of continuous use; auto-off after 8 minutes of non-use |
Auto-off | after 8 minutes, 60 minutes, disabled |
Environment | -5 to 50°C (23 to 122°F); RH max 100% |
Dimensions | 152 x 58 x 30 mm (6.0 x 2.3 x 1.2”) |
Weight | 205 g (7.2 oz.) |
Ordering Information | HI9814 is supplied with HI1285-7 multiparameter probe, HI9814-0 Quick Cal buffer solution sachet, HI70031 1413 µS/cm calibration solution sachet (3), HI700663 pH electrode cleaning solution sachet for soil deposits (3), 1.5 AAA batteries (3), and instructions. |
SKU | 8776 |
---|---|
Manufacturer's Suggested Retail Price | $324.95 |
Dimensional/Billable Weight (lbs) | 1.00 |
Actual Product Weight | 0.5 |
Length (in.) | 6 |
Width (in.) | 3 |
Height (in.) | 10 |
Model | HI9814 |
Brand | Hanna |
Vendor Item # | HI9814 |
Manufacturer Warranty | Yes |